RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0803007382 - Archived data from Fri, 05. February 2021 10:55:14 CET


This is all the information about APD 0803007382. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0803007382
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F14
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 386.8 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 53
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.350416 V     T = -25 °C: 351.0341053 V
Voltage for Gain 150: T = +20 °C: 395.2679763 V     T = -25 °C: 358.6187558 V
Voltage for Gain 200: T = +20 °C: 399.5836941 V     T = -25 °C: 362.8631621 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.664113426 V-1     T = -25 °C: 5.096627257 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.807622134 V-1     T = -25 °C: 9.262229033 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.64340981 V-1     T = -25 °C: 13.81401628 V-1
Break-through voltage: T = +20 °C: 415.2396744 V     T = -25 °C: 378.7318769 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:15:54 CET oafedulidis Assigned to capsule by script
16. Dec 2021 13:42:49 CET oafedulidis Updated box and position via API.
21. Apr 2021 14:46:18 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:55:14 CET jreher Updated box and position via API.
03. Feb 2021 18:20:49 CET jreher Updated box and position via API.
11. Aug 2020 17:27:45 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:38:07 CET jreher Updated APD location via API.
25. Nov 2019 17:15:08 CET jreher Updated box and position via API.
04. Jul 2019 11:12:29 CEST jreher Updated APD location via API.
18. Jun 2019 13:18:51 CEST jgrochowski Updated APD batch assignment via API.
22. Jun 2016 15:22:35 CEST Tobias Imported from Hamamatsu datasheet.