RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2803030991 - Archived data from Wed, 16. June 2021 16:03:56 CEST


This is all the information about APD 2803030991. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2803030991
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D08
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 381.3 V
Dark current: 8.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 60
Position in Box: 33
EP1 batch: 72
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.6761196 V     T = -25 °C: 346.1248886 V
Voltage for Gain 150: T = +20 °C: 389.4871885 V     T = -25 °C: 353.4806525 V
Voltage for Gain 200: T = +20 °C: 393.8208091 V     T = -25 °C: 357.6016479 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.449418872 V-1     T = -25 °C: 4.921698349 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.718410342 V-1     T = -25 °C: 9.210488092 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.32367406 V-1     T = -25 °C: 16.67447704 V-1
Break-through voltage: T = +20 °C: 408.3787544 V     T = -25 °C: 372.1636479 V
   
Notes:


Version history

Time Author Change comment
27. Jun 2022 12:42:44 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:56 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:11 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:52 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:22:13 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:59:16 CET jreher Updated box and position via API.
03. Feb 2021 18:24:46 CET jreher Updated box and position via API.
11. Aug 2020 17:39:00 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:53 CET jreher Updated APD location via API.
25. Nov 2019 17:17:38 CET jreher Updated box and position via API.
13. Sep 2019 10:28:54 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:13:10 CEST markus.moritz
25. Jul 2019 12:12:29 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:33 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:33 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:05:21 CEST Tobias Imported from Hamamatsu datasheet.