RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2802030941 - Archived data from Fri, 05. February 2021 10:59:12 CET


This is all the information about APD 2802030941. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2802030941
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E02
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.7 V
Dark current: 5.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 64
Position in Box: 43
EP1 batch: 72
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.6148816 V     T = -25 °C: 345.4529322 V
Voltage for Gain 150: T = +20 °C: 388.5485722 V     T = -25 °C: 352.8651718 V
Voltage for Gain 200: T = +20 °C: 392.9600855 V     T = -25 °C: 357.0240712 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.378515791 V-1     T = -25 °C: 4.746101299 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.442282277 V-1     T = -25 °C: 9.567879662 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.46653849 V-1     T = -25 °C: 15.23768934 V-1
Break-through voltage: T = +20 °C: 408.9747802 V     T = -25 °C: 372.3921021 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:16:17 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:18:35 CEST oafedulidis Updated box and position via API.
03. May 2021 10:25:07 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:59:12 CET jreher Updated box and position via API.
03. Feb 2021 18:24:41 CET jreher Updated box and position via API.
11. Aug 2020 17:38:56 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:44 CET jreher Updated APD location via API.
25. Nov 2019 17:17:35 CET jreher Updated box and position via API.
13. Sep 2019 10:28:31 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:05:33 CEST markus.moritz
25. Jul 2019 12:12:27 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:27 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:32 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:05:12 CEST Tobias Imported from Hamamatsu datasheet.