RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2801030888 - Archived data from Wed, 03. February 2021 18:24:39 CET


This is all the information about APD 2801030888. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2801030888
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C09
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 381.6 V
Dark current: 9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 84
Position in Box: 11
EP1 batch: 71
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.9888593 V     T = -25 °C: 346.6185315 V
Voltage for Gain 150: T = +20 °C: 389.8294492 V     T = -25 °C: 353.9671074 V
Voltage for Gain 200: T = +20 °C: 394.1914473 V     T = -25 °C: 358.0868931 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.608521224 V-1     T = -25 °C: 4.694300171 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.102995905 V-1     T = -25 °C: 9.532208938 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.14716244 V-1     T = -25 °C: 15.15835138 V-1
Break-through voltage: T = +20 °C: 408.9657634 V     T = -25 °C: 372.2859425 V
   
Notes:


Version history

Time Author Change comment
18. May 2022 09:59:27 CEST oafedulidis Assigned to capsule by script
28. Apr 2021 13:28:25 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:59:09 CET jreher Updated box and position via API.
03. Feb 2021 18:24:39 CET jreher Updated box and position via API.
11. Aug 2020 17:38:52 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:42 CET jreher Updated APD location via API.
25. Nov 2019 17:17:33 CET jreher Updated box and position via API.
13. Sep 2019 10:27:59 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 12:58:22 CEST markus.moritz
25. Jul 2019 12:12:45 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:25 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:31 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:05:03 CEST Tobias Imported from Hamamatsu datasheet.