RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2710030804 - Archived data from Tue, 11. August 2020 17:38:43 CEST


This is all the information about APD 2710030804. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2710030804
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D05
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 386.2 V
Dark current: 14.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 83
Position in Box: 16
EP1 batch: 69
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.2701614 V     T = -25 °C: 350.4928838 V
Voltage for Gain 150: T = +20 °C: 394.1451387 V     T = -25 °C: 357.9217156 V
Voltage for Gain 200: T = +20 °C: 398.5205027 V     T = -25 °C: 362.0873284 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.514415715 V-1     T = -25 °C: 4.688167577 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.858426487 V-1     T = -25 °C: 9.498028122 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.47968477 V-1     T = -25 °C: 15.01066666 V-1
Break-through voltage: T = +20 °C: 413.4771771 V     T = -25 °C: 376.996429 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:33:42 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:27 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:46 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:26 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:59:01 CET jreher Updated box and position via API.
03. Feb 2021 18:24:31 CET jreher Updated box and position via API.
11. Aug 2020 17:38:43 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:32 CET jreher Updated APD location via API.
25. Nov 2019 17:17:29 CET jreher Updated box and position via API.
10. Sep 2019 11:23:04 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 12:42:31 CEST markus.moritz
25. Jul 2019 12:13:16 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:18 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:30 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:46 CEST Tobias Imported from Hamamatsu datasheet.