Show Hamamatsu Avalanche Photo Diode 2710030801 - Archived data from Wed, 03. February 2021 18:24:31 CET
This is all the information about APD 2710030801. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2710030801 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C07 |
Break-through voltage: | 415 V |
Voltage for Gain 100 (T=+25°C): | 386.7 V |
Dark current: | 13.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 83 |
Position in Box: | 14 |
EP1 batch: | 69 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 26. Aug 2019 |
Sent for analysis after irradiation: | 02. Sep 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Aug 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 31. Aug 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 386.6298127 V T = -25 °C: 350.7626662 V |
Voltage for Gain 150: | T = +20 °C: 394.5380704 V T = -25 °C: 358.227339 V |
Voltage for Gain 200: | T = +20 °C: 398.907209 V T = -25 °C: 362.4260739 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.367209909 V-1 T = -25 °C: 4.940020674 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.458674914 V-1 T = -25 °C: 9.169901172 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.63502928 V-1 T = -25 °C: 14.38466966 V-1 |
Break-through voltage: | T = +20 °C: 414.5209248 V T = -25 °C: 377.7722816 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2021 10:39:57 CET | oafedulidis | Assigned to capsule by script |
21. Apr 2021 11:02:31 CEST | jreher | Updated box and position via API. |
05. Feb 2021 10:59:01 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:24:31 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:38:43 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:43:32 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:17:29 CET | jreher | Updated box and position via API. |
10. Sep 2019 11:23:04 CEST | jgrochowski | Updated APD batch assignment via API. |
04. Sep 2019 12:31:52 CEST | markus.moritz | |
25. Jul 2019 12:13:16 CEST | spankonin | Updated APD batch assignment via API. |
05. Jul 2019 13:47:18 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:30 CET | Tobias | Corrected dark current unit. |
24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
18. May 2018 12:04:45 CEST | Tobias | Imported from Hamamatsu datasheet. |