Show Hamamatsu Avalanche Photo Diode 2710030773 - Archived data from Tue, 11. August 2020 17:38:38 CEST


This is all the information about APD 2710030773. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2710030773
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2710030773/1912021185
Unit: #932 (barcode 1309010240)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.5 V
Dark current: 18 nA
   
Screening Logistics:  
Available: No
Storage Box: 82
Position in Box: 38
EP1 batch: 69
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.529814 V     T = -25 °C: 344.1025353 V
Voltage for Gain 150: T = +20 °C: 387.3458296 V     T = -25 °C: 351.4941202 V
Voltage for Gain 200: T = +20 °C: 391.695317 V     T = -25 °C: 355.6168893 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.438122276 V-1     T = -25 °C: 4.87665728 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.662762246 V-1     T = -25 °C: 9.010524028 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.01101389 V-1     T = -25 °C: 15.95285428 V-1
Break-through voltage: T = +20 °C: 407.483766 V     T = -25 °C: 371.0991557 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:58:56 CET jreher Updated box and position via API.
03. Feb 2021 18:24:26 CET jreher Updated box and position via API.
11. Aug 2020 17:38:38 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:52:39 CEST jreher Assigned to capsule by script
13. Feb 2020 14:21:52 CET jreher Updated box and position via API.
27. Nov 2019 19:43:22 CET jreher Updated APD location via API.
25. Nov 2019 17:17:26 CET jreher Updated box and position via API.
10. Sep 2019 11:22:40 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 11:50:43 CEST markus.moritz
25. Jul 2019 12:13:14 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:12 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:29 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:35 CEST Tobias Imported from Hamamatsu datasheet.