Subdetector specification:  
Serial: 2710030758
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H06
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 386 V
Dark current: 14.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 82
Position in Box: 17
EP1 batch: 68
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.0469003 V     T = -25 °C: 350.1456993 V
Voltage for Gain 150: T = +20 °C: 393.936218 V     T = -25 °C: 357.6841572 V
Voltage for Gain 200: T = +20 °C: 398.3384707 V     T = -25 °C: 361.9003021 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.533847689 V-1     T = -25 °C: 4.782093008 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.954809164 V-1     T = -25 °C: 9.572227429 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.80871974 V-1     T = -25 °C: 15.00469303 V-1
Break-through voltage: T = +20 °C: 412.102646 V     T = -25 °C: 377.2478437 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:38:34 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:52 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:01:04 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:50 CEST oafedulidis Updated box and position via API.
03. May 2021 10:27:10 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:58:54 CET jreher Updated box and position via API.
03. Feb 2021 18:24:25 CET jreher Updated box and position via API.
11. Aug 2020 17:38:35 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:21 CET jreher Updated APD location via API.
25. Nov 2019 17:17:24 CET jreher Updated box and position via API.
10. Sep 2019 11:22:21 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 11:46:15 CEST markus.moritz
25. Jul 2019 12:13:32 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:28 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:30 CEST Tobias Imported from Hamamatsu datasheet.