RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2709030737 - Archived data from Tue, 11. August 2020 17:38:33 CEST


This is all the information about APD 2709030737. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2709030737
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F02
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.7 V
Dark current: 8.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 82
Position in Box: 11
EP1 batch: 68
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.170725 V     T = -25 °C: 350.4071056 V
Voltage for Gain 150: T = +20 °C: 394.0890742 V     T = -25 °C: 357.8870668 V
Voltage for Gain 200: T = +20 °C: 398.4939211 V     T = -25 °C: 362.0765499 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.501311139 V-1     T = -25 °C: 4.701916129 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.809024703 V-1     T = -25 °C: 9.459378252 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.37548873 V-1     T = -25 °C: 14.95652336 V-1
Break-through voltage: T = +20 °C: 413.6099509 V     T = -25 °C: 377.1179478 V
   
Notes:


Version history

Time Author Change comment
19. May 2022 15:27:25 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:00:44 CEST oafedulidis Updated box and position via API.
03. May 2021 10:27:10 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:58:53 CET jreher Updated box and position via API.
03. Feb 2021 18:24:24 CET jreher Updated box and position via API.
11. Aug 2020 17:38:33 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:21 CET jreher Updated APD location via API.
25. Nov 2019 17:17:24 CET jreher Updated box and position via API.
10. Sep 2019 11:22:20 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 11:33:42 CEST markus.moritz
25. Jul 2019 12:13:32 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:28 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:27 CEST Tobias Imported from Hamamatsu datasheet.