Show Hamamatsu Avalanche Photo Diode 2709030727 - Archived data from Fri, 05. February 2021 10:58:52 CET
This is all the information about APD 2709030727. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2709030727 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E02 |
Break-through voltage: | 417 V |
Voltage for Gain 100 (T=+25°C): | 388.3 V |
Dark current: | 9.1 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 82 |
Position in Box: | 7 |
EP1 batch: | 68 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 26. Aug 2019 |
Sent for analysis after irradiation: | 02. Sep 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Aug 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 31. Aug 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 388.3181516 V T = -25 °C: 352.1420662 V |
Voltage for Gain 150: | T = +20 °C: 396.240304 V T = -25 °C: 359.67648 V |
Voltage for Gain 200: | T = +20 °C: 400.634207 V T = -25 °C: 363.871084 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.454413283 V-1 T = -25 °C: 4.77994192 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.688215824 V-1 T = -25 °C: 9.708920304 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.17731836 V-1 T = -25 °C: 15.35200239 V-1 |
Break-through voltage: | T = +20 °C: 415.8340075 V T = -25 °C: 379.1867925 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
26. Oct 2021 10:53:02 CEST | oafedulidis | Assigned to capsule by script |
28. Apr 2021 13:28:11 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:58:52 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:24:23 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:38:32 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:43:20 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:17:23 CET | jreher | Updated box and position via API. |
10. Sep 2019 11:22:19 CEST | jgrochowski | Updated APD batch assignment via API. |
04. Sep 2019 11:30:43 CEST | markus.moritz | |
25. Jul 2019 12:13:31 CEST | spankonin | Updated APD batch assignment via API. |
05. Jul 2019 13:47:09 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:28 CET | Tobias | Corrected dark current unit. |
24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
18. May 2018 12:04:24 CEST | Tobias | Imported from Hamamatsu datasheet. |