RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2709030721 - Archived data from Mon, 03. May 2021 10:27:08 CEST


This is all the information about APD 2709030721. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2709030721
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G06
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 385.3 V
Dark current: 10.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 82
Position in Box: 2
EP1 batch: 67
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.6068059 V     T = -25 °C: 348.8156795 V
Voltage for Gain 150: T = +20 °C: 392.4428642 V     T = -25 °C: 356.2493345 V
Voltage for Gain 200: T = +20 °C: 396.7791707 V     T = -25 °C: 360.4190191 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.381617882 V-1     T = -25 °C: 4.933793467 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.576806393 V-1     T = -25 °C: 9.139795169 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.90578934 V-1     T = -25 °C: 16.3191746 V-1
Break-through voltage: T = +20 °C: 412.0006502 V     T = -25 °C: 375.5562382 V
   
Notes:


Version history

Time Author Change comment
25. Sep 2021 15:59:12 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:02:10 CEST oafedulidis Updated box and position via API.
03. May 2021 10:27:08 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:58:52 CET jreher Updated box and position via API.
03. Feb 2021 18:24:22 CET jreher Updated box and position via API.
11. Aug 2020 17:38:31 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:20 CET jreher Updated APD location via API.
25. Nov 2019 17:17:23 CET jreher Updated box and position via API.
10. Sep 2019 11:22:19 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 11:29:14 CEST markus.moritz
25. Jul 2019 12:13:47 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:09 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:28 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:21 CEST Tobias Imported from Hamamatsu datasheet.