Subdetector specification:  
Serial: 2709030681
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.9 V
Dark current: 11.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 81
Position in Box: 23
EP1 batch: 66
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.1636261 V     T = -25 °C: 348.3498249 V
Voltage for Gain 150: T = +20 °C: 391.9665361 V     T = -25 °C: 355.7275913 V
Voltage for Gain 200: T = +20 °C: 396.3005992 V     T = -25 °C: 359.8351128 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.602633631 V-1     T = -25 °C: 4.802444462 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.104287022 V-1     T = -25 °C: 9.883035674 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.26932525 V-1     T = -25 °C: 15.82961502 V-1
Break-through voltage: T = +20 °C: 411.9129466 V     T = -25 °C: 375.1274005 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2022 10:01:34 CET oafedulidis Assigned to capsule by script
30. Aug 2021 14:07:12 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:58:46 CET jreher Updated box and position via API.
03. Feb 2021 18:24:17 CET jreher Updated box and position via API.
11. Aug 2020 17:38:25 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:43:10 CET jreher Updated APD location via API.
25. Nov 2019 17:17:20 CET jreher Updated box and position via API.
10. Sep 2019 11:21:38 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 11:11:59 CEST markus.moritz
25. Jul 2019 12:14:00 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:47:02 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:27 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:04:14 CEST Tobias Imported from Hamamatsu datasheet.