RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2708030603 - Archived data from Wed, 03. February 2021 18:24:09 CET


This is all the information about APD 2708030603. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2708030603
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2402026037/2708030603
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.3 V
Dark current: 9.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 80
Position in Box: 21
EP1 batch: 65
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.1534974 V     T = -25 °C: 345.8366127 V
Voltage for Gain 150: T = +20 °C: 388.9407693 V     T = -25 °C: 353.1912259 V
Voltage for Gain 200: T = +20 °C: 393.2817384 V     T = -25 °C: 357.3229651 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.602234286 V-1     T = -25 °C: 5.006012624 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.157374041 V-1     T = -25 °C: 9.374995891 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.294717 V-1     T = -25 °C: 14.80597277 V-1
Break-through voltage: T = +20 °C: 408.9202937 V     T = -25 °C: 372.6930588 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:58:38 CET jreher Updated box and position via API.
03. Feb 2021 18:24:09 CET jreher Updated box and position via API.
11. Aug 2020 17:38:15 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:46:12 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:55 CET jreher Updated box and position via API.
27. Nov 2019 19:42:59 CET jreher Updated APD location via API.
25. Nov 2019 17:17:15 CET jreher Updated box and position via API.
10. Sep 2019 11:20:56 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 10:53:24 CEST markus.moritz
25. Jul 2019 12:14:14 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:54 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:25 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:03:56 CEST Tobias Imported from Hamamatsu datasheet.