Serial: 2707030542
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 387.5 V
Dark current: 6.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 93
Position in Box: 36
EP1 batch: 63
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.445247 V     T = -25 °C: 352.3480414 V
Voltage for Gain 150: T = +20 °C: 396.236082 V     T = -25 °C: 359.8578638 V
Voltage for Gain 200: T = +20 °C: 400.5615573 V     T = -25 °C: 364.0503491 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.479738262 V-1     T = -25 °C: 4.719655701 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.869327786 V-1     T = -25 °C: 9.49068761 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.56960557 V-1     T = -25 °C: 15.00954296 V-1
Break-through voltage: T = +20 °C: 414.7424621 V     T = -25 °C: 378.395002 V
   
Notes:


Version history

Time Author Change comment
27. Aug 2021 10:30:27 CEST oafedulidis Updated box and position via API.
03. May 2021 10:26:08 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:58:30 CET jreher Updated box and position via API.
03. Feb 2021 18:24:00 CET jreher Updated box and position via API.
11. Aug 2020 17:38:05 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:48 CET jreher Updated APD location via API.
25. Nov 2019 17:17:10 CET jreher Updated box and position via API.
10. Sep 2019 11:19:58 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 10:23:30 CEST markus.moritz
25. Jul 2019 12:14:41 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:46 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:23 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:03:30 CEST Tobias Imported from Hamamatsu datasheet.