RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0802007350


This is all the information about APD 0802007350. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0802007350
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0802007350/0805007538
Unit: #3915 (barcode 1309039289)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E14
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 392.1 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 182
Position in Box: 37
EP1 batch: none
EP1 batch after irradiation: 10104
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 09. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 391.4727625 V     T = -25 °C: 355.1280865 V
Voltage for Gain 150: T = +20 °C: 399.3549095 V     T = -25 °C: 362.7982871 V
Voltage for Gain 200: T = +20 °C: 403.724582 V     T = -25 °C: 367.0659025 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.445993296 V-1     T = -25 °C: 4.728501837 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.790234226 V-1     T = -25 °C: 9.534912901 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.5783328 V-1     T = -25 °C: 15.11917012 V-1
Break-through voltage: T = +20 °C: 418.7539368 V     T = -25 °C: 382.5623202 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
16. Nov 2022 10:57:55 CET oafedulidis Assigned to capsule by script
01. Dec 2021 12:56:47 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:11:49 CET jreher Updated box and position via API.
11. Aug 2020 17:30:09 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:01:13 CET jreher Updated APD location via API.
25. Nov 2019 17:25:14 CET jreher Updated box and position via API.
13. Aug 2019 12:19:55 CEST jreher Updated APD location via API.
22. Jul 2019 10:51:44 CEST spankonin Updated APD batch assignment via API.
10. Jul 2019 12:27:34 CEST markus.moritz
22. Jun 2016 15:22:35 CEST Tobias Imported from Hamamatsu datasheet.