Show Hamamatsu Avalanche Photo Diode 2706030468 - Archived data from Tue, 11. August 2020 17:54:54 CEST


This is all the information about APD 2706030468. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2706030468
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F12
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.3 V
Dark current: 16.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 78
Position in Box: 38
EP1 batch: 149
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:58:25 CET jreher Updated box and position via API.
03. Feb 2021 18:23:55 CET jreher Updated box and position via API.
11. Aug 2020 17:54:54 CEST jreher Updated APD location via API.
29. Nov 2019 11:50:24 CET jreher Updated APD location via API.
27. Nov 2019 19:42:38 CET jreher Updated APD location via API.
25. Nov 2019 17:17:07 CET jreher Updated box and position via API.
17. Sep 2019 12:08:18 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:46:39 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:22 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:03:18 CEST Tobias Imported from Hamamatsu datasheet.