Subdetector specification:  
Serial: 2706030448
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Giessen
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C10
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.7 V
Dark current: 11.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 78
Position in Box: 22
EP1 batch: 62
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.8952787 V     T = -25 °C: 347.5449941 V
Voltage for Gain 150: T = +20 °C: 390.7792541 V     T = -25 °C: 354.9432658 V
Voltage for Gain 200: T = +20 °C: 395.1543429 V     T = -25 °C: 359.0871438 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.625006289 V-1     T = -25 °C: 4.725621936 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.179536435 V-1     T = -25 °C: 9.579523582 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.36043386 V-1     T = -25 °C: 15.22552222 V-1
Break-through voltage: T = +20 °C: 410.0047806 V     T = -25 °C: 373.7583299 V
   
Notes:


Version history

Time Author Change comment
29. Apr 2021 17:04:36 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:26:11 CET jreher Updated box and position via API.
05. Feb 2021 10:58:23 CET jreher Updated box and position via API.
03. Feb 2021 18:23:53 CET jreher Updated box and position via API.
11. Aug 2020 17:54:53 CEST jreher Updated APD location via API.
11. Aug 2020 17:38:00 CEST jreher Updated APD characteristics via API.
29. Nov 2019 11:50:23 CET jreher Updated APD location via API.
27. Nov 2019 19:42:37 CET jreher Updated APD location via API.
25. Nov 2019 17:17:06 CET jreher Updated box and position via API.
06. Sep 2019 13:13:36 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 14:59:54 CEST markus.moritz
08. Jul 2019 14:56:46 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:38 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:21 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:03:12 CEST Tobias Imported from Hamamatsu datasheet.