RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2705030376 - Archived data from Wed, 14. April 2021 18:46:25 CEST


This is all the information about APD 2705030376. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2705030376
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2504027860/2705030376
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: B08
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 384.2 V
Dark current: 9.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 77
Position in Box: 28
EP1 batch: 61
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.0445012 V     T = -25 °C: 349.3867753 V
Voltage for Gain 150: T = +20 °C: 392.9295897 V     T = -25 °C: 356.8162266 V
Voltage for Gain 200: T = +20 °C: 397.3129978 V     T = -25 °C: 360.9834505 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.570907265 V-1     T = -25 °C: 4.717453226 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.012442333 V-1     T = -25 °C: 9.594856887 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.98367433 V-1     T = -25 °C: 15.25087491 V-1
Break-through voltage: T = +20 °C: 412.0361263 V     T = -25 °C: 375.5986336 V
   
Notes:


Version history

Time Author Change comment
15. Apr 2021 16:58:05 CEST jreher Updated box and position via API.
14. Apr 2021 18:46:25 CEST oafedulidis Assigned to capsule by script
05. Feb 2021 10:58:13 CET jreher Updated box and position via API.
03. Feb 2021 18:23:46 CET jreher Updated box and position via API.
11. Aug 2020 17:37:52 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:26 CET jreher Updated APD location via API.
25. Nov 2019 17:17:01 CET jreher Updated box and position via API.
06. Sep 2019 13:13:16 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 14:37:23 CEST markus.moritz
08. Jul 2019 14:56:27 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:31 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:20 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:53 CEST Tobias Imported from Hamamatsu datasheet.