Show Hamamatsu Avalanche Photo Diode 2705030362 - Archived data from Tue, 11. August 2020 17:37:50 CEST
This is all the information about APD 2705030362. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2705030362 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C09 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 384.3 V |
Dark current: | 12.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 77 |
Position in Box: | 18 |
EP1 batch: | 60 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 26. Aug 2019 |
Sent for analysis after irradiation: | 02. Sep 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Aug 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 31. Aug 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 384.4811679 V T = -25 °C: 348.9210616 V |
Voltage for Gain 150: | T = +20 °C: 392.3416893 V T = -25 °C: 356.367828 V |
Voltage for Gain 200: | T = +20 °C: 396.7102231 V T = -25 °C: 360.5489466 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.461083647 V-1 T = -25 °C: 4.918611974 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.697770915 V-1 T = -25 °C: 9.147474886 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.22601783 V-1 T = -25 °C: 16.23965568 V-1 |
Break-through voltage: | T = +20 °C: 412.4451187 V T = -25 °C: 376.0281412 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:58:12 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:23:45 CET | jreher | Updated box and position via API. |
29. Jan 2021 10:25:29 CET | jreher | Assigned to capsule by script |
06. Oct 2020 16:50:48 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:37:50 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:42:25 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:17:01 CET | jreher | Updated box and position via API. |
06. Sep 2019 13:12:51 CEST | spankonin | Updated APD batch assignment via API. |
03. Sep 2019 14:29:55 CEST | markus.moritz | |
08. Jul 2019 14:56:12 CEST | spankonin | Updated APD batch assignment via API. |
05. Jul 2019 13:46:30 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:19 CET | Tobias | Corrected dark current unit. |
24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
18. May 2018 12:02:50 CEST | Tobias | Imported from Hamamatsu datasheet. |