Subdetector specification:  
Serial: 2704030279
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C14
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.5 V
Dark current: 18.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 76
Position in Box: 24
EP1 batch: 59
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.5620582 V     T = -25 °C: 347.099081 V
Voltage for Gain 150: T = +20 °C: 390.429544 V     T = -25 °C: 354.5252938 V
Voltage for Gain 200: T = +20 °C: 394.8085368 V     T = -25 °C: 358.6850144 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.42595848 V-1     T = -25 °C: 4.862123026 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.60397011 V-1     T = -25 °C: 8.958218726 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.8507076 V-1     T = -25 °C: 15.86188908 V-1
Break-through voltage: T = +20 °C: 410.6800818 V     T = -25 °C: 374.3115113 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 18:52:22 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:26:53 CET jreher Updated box and position via API.
05. Feb 2021 10:58:05 CET jreher Updated box and position via API.
03. Feb 2021 18:23:38 CET jreher Updated box and position via API.
11. Aug 2020 17:37:42 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:15 CET jreher Updated APD location via API.
25. Nov 2019 17:16:56 CET jreher Updated box and position via API.
06. Sep 2019 13:12:08 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 12:21:33 CEST markus.moritz
08. Jul 2019 14:55:56 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:22 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:17 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:32 CEST Tobias Imported from Hamamatsu datasheet.