RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2704030257 - Archived data from Wed, 03. February 2021 18:23:36 CET


This is all the information about APD 2704030257. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2704030257
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C06
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.4 V
Dark current: 10.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 76
Position in Box: 8
EP1 batch: 58
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.412822 V     T = -25 °C: 349.7066271 V
Voltage for Gain 150: T = +20 °C: 393.2526615 V     T = -25 °C: 357.1296156 V
Voltage for Gain 200: T = +20 °C: 397.6070867 V     T = -25 °C: 361.3017464 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.473282648 V-1     T = -25 °C: 4.651624202 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.793809649 V-1     T = -25 °C: 9.295502093 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.34415705 V-1     T = -25 °C: 14.65688397 V-1
Break-through voltage: T = +20 °C: 413.3367249 V     T = -25 °C: 376.7339866 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:58:03 CET jreher Updated box and position via API.
03. Feb 2021 18:23:36 CET jreher Updated box and position via API.
11. Aug 2020 17:37:39 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:13 CET jreher Updated APD location via API.
25. Nov 2019 17:16:55 CET jreher Updated box and position via API.
06. Sep 2019 13:12:07 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 12:14:23 CEST markus.moritz
08. Jul 2019 14:55:42 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:21 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:17 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:24 CEST Tobias Imported from Hamamatsu datasheet.