RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2703030227 - Archived data from Tue, 11. August 2020 17:37:37 CEST


This is all the information about APD 2703030227. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2703030227
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E05
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.2 V
Dark current: 14.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 178
Position in Box: 50
EP1 batch: 58
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.227213 V     T = -25 °C: 343.9350576 V
Voltage for Gain 150: T = +20 °C: 387.0841723 V     T = -25 °C: 351.3703486 V
Voltage for Gain 200: T = +20 °C: 391.4850492 V     T = -25 °C: 355.5249044 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.542606747 V-1     T = -25 °C: 4.692979939 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.82726124 V-1     T = -25 °C: 9.060778502 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.34928876 V-1     T = -25 °C: 16.14480507 V-1
Break-through voltage: T = +20 °C: 407.4313673 V     T = -25 °C: 371.122974 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 09:59:36 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:00:13 CEST oafedulidis Updated box and position via API.
03. May 2021 10:24:51 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:58:00 CET jreher Updated box and position via API.
03. Feb 2021 18:23:33 CET jreher Updated box and position via API.
11. Aug 2020 17:37:37 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:05 CET jreher Updated APD location via API.
25. Nov 2019 17:16:54 CET jreher Updated box and position via API.
06. Sep 2019 13:11:43 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 11:58:19 CEST markus.moritz
08. Jul 2019 14:55:41 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:16 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:17 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:21 CEST Tobias Imported from Hamamatsu datasheet.