RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2703030213 - Archived data from Wed, 03. February 2021 18:23:32 CET


This is all the information about APD 2703030213. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2703030213
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.7 V
Dark current: 11.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 75
Position in Box: 38
EP1 batch: 58
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.8261351 V     T = -25 °C: 343.6127872 V
Voltage for Gain 150: T = +20 °C: 386.6660424 V     T = -25 °C: 350.9990378 V
Voltage for Gain 200: T = +20 °C: 391.0323322 V     T = -25 °C: 355.119818 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.644172642 V-1     T = -25 °C: 4.784427323 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.145024368 V-1     T = -25 °C: 9.351396754 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.18800946 V-1     T = -25 °C: 14.97802338 V-1
Break-through voltage: T = +20 °C: 406.7313767 V     T = -25 °C: 370.4160763 V
   
Notes:


Version history

Time Author Change comment
20. Oct 2021 09:32:17 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:00:51 CEST jreher Updated box and position via API.
05. Feb 2021 10:57:59 CET jreher Updated box and position via API.
03. Feb 2021 18:23:32 CET jreher Updated box and position via API.
11. Aug 2020 17:37:35 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:04 CET jreher Updated APD location via API.
25. Nov 2019 17:16:53 CET jreher Updated box and position via API.
06. Sep 2019 13:11:42 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 11:49:42 CEST markus.moritz
08. Jul 2019 14:55:40 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:15 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:16 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:18 CEST Tobias Imported from Hamamatsu datasheet.