RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2703030212 - Archived data from Wed, 21. April 2021 11:03:13 CEST


This is all the information about APD 2703030212. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2703030212
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.8 V
Dark current: 15.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 75
Position in Box: 37
EP1 batch: 58
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.8503167 V     T = -25 °C: 342.7013078 V
Voltage for Gain 150: T = +20 °C: 385.6580298 V     T = -25 °C: 350.0478808 V
Voltage for Gain 200: T = +20 °C: 389.9982814 V     T = -25 °C: 354.1447061 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.695468385 V-1     T = -25 °C: 5.102033535 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.273423642 V-1     T = -25 °C: 9.664734548 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.51749231 V-1     T = -25 °C: 15.09861284 V-1
Break-through voltage: T = +20 °C: 405.6047273 V     T = -25 °C: 369.2366235 V
   
Notes:


Version history

Time Author Change comment
25. Sep 2021 15:59:50 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:03:13 CEST jreher Updated box and position via API.
05. Feb 2021 10:57:59 CET jreher Updated box and position via API.
03. Feb 2021 18:23:32 CET jreher Updated box and position via API.
11. Aug 2020 17:37:35 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:42:04 CET jreher Updated APD location via API.
25. Nov 2019 17:16:53 CET jreher Updated box and position via API.
06. Sep 2019 13:11:42 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 11:48:50 CEST markus.moritz
08. Jul 2019 14:55:40 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:15 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:16 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:18 CEST Tobias Imported from Hamamatsu datasheet.