Show Hamamatsu Avalanche Photo Diode 2703030209 - Archived data from Wed, 03. February 2021 18:23:31 CET
This is all the information about APD 2703030209. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2703030209 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D04 |
Break-through voltage: | 409 V |
Voltage for Gain 100 (T=+25°C): | 379.8 V |
Dark current: | 10.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 75 |
Position in Box: | 34 |
EP1 batch: | 58 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 26. Aug 2019 |
Sent for analysis after irradiation: | 02. Sep 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Aug 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 31. Aug 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 379.831616 V T = -25 °C: 344.5921793 V |
Voltage for Gain 150: | T = +20 °C: 387.6707127 V T = -25 °C: 351.9540814 V |
Voltage for Gain 200: | T = +20 °C: 392.029751 V T = -25 °C: 356.0707395 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.68109468 V-1 T = -25 °C: 4.478169497 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.283316247 V-1 T = -25 °C: 9.469907567 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.43427526 V-1 T = -25 °C: 15.24967926 V-1 |
Break-through voltage: | T = +20 °C: 408.0640823 V T = -25 °C: 371.6169493 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
29. Apr 2021 17:05:44 CEST | oafedulidis | Assigned to capsule by script |
16. Feb 2021 12:28:34 CET | jreher | Updated box and position via API. |
05. Feb 2021 10:57:58 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:23:31 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:37:34 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:42:04 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:16:52 CET | jreher | Updated box and position via API. |
06. Sep 2019 13:11:42 CEST | spankonin | Updated APD batch assignment via API. |
03. Sep 2019 11:47:24 CEST | markus.moritz | |
08. Jul 2019 14:55:40 CEST | spankonin | Updated APD batch assignment via API. |
05. Jul 2019 13:46:15 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:16 CET | Tobias | Corrected dark current unit. |
24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
18. May 2018 12:02:18 CEST | Tobias | Imported from Hamamatsu datasheet. |