Show Hamamatsu Avalanche Photo Diode 2702030146 - Archived data from Fri, 06. September 2019 13:11:21 CEST
This is all the information about APD 2702030146. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2702030146 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 74 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C13 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.8 V |
Dark current: | 9.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 74 |
Position in Box: | 45 |
EP1 batch: | 56 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 26. Aug 2019 |
Sent for analysis after irradiation: | 02. Sep 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Aug 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 31. Aug 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:57:52 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:23:25 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:37:27 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:41:54 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:16:48 CET | jreher | Updated box and position via API. |
06. Sep 2019 13:11:21 CEST | spankonin | Updated APD batch assignment via API. |
03. Sep 2019 11:21:01 CEST | markus.moritz | |
08. Jul 2019 14:55:10 CEST | spankonin | Updated APD batch assignment via API. |
05. Jul 2019 13:46:08 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:13:15 CET | Tobias | Corrected dark current unit. |
24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
18. May 2018 12:02:04 CEST | Tobias | Imported from Hamamatsu datasheet. |