Serial: 2702030108
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 382.4 V
Dark current: 7.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 74
Position in Box: 34
EP1 batch: 56
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.6224801 V     T = -25 °C: 347.2590353 V
Voltage for Gain 150: T = +20 °C: 390.4976933 V     T = -25 °C: 354.6367299 V
Voltage for Gain 200: T = +20 °C: 394.8600715 V     T = -25 °C: 358.7766944 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.6925385 V-1     T = -25 °C: 4.841011781 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.286036046 V-1     T = -25 °C: 9.700783871 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.56467406 V-1     T = -25 °C: 15.47363368 V-1
Break-through voltage: T = +20 °C: 410.6642113 V     T = -25 °C: 374.0778004 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 18:52:17 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:26:51 CET jreher Updated box and position via API.
05. Feb 2021 10:57:51 CET jreher Updated box and position via API.
03. Feb 2021 18:23:23 CET jreher Updated box and position via API.
11. Aug 2020 17:37:25 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:53 CET jreher Updated APD location via API.
25. Nov 2019 17:16:48 CET jreher Updated box and position via API.
06. Sep 2019 13:10:54 CEST spankonin Updated APD batch assignment via API.
03. Sep 2019 10:51:36 CEST markus.moritz
08. Jul 2019 14:55:09 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:07 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:14 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:02:01 CEST Tobias Imported from Hamamatsu datasheet.