RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2701030063 - Archived data from Fri, 18. December 2020 14:00:39 CET


This is all the information about APD 2701030063. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2701030063
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C06
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.7 V
Dark current: 7.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 74
Position in Box: 8
EP1 batch: 55
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.8469612 V     T = -25 °C: 348.1995399 V
Voltage for Gain 150: T = +20 °C: 391.7032224 V     T = -25 °C: 355.6341831 V
Voltage for Gain 200: T = +20 °C: 396.0636415 V     T = -25 °C: 359.7970237 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.676187143 V-1     T = -25 °C: 4.813052258 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.269515737 V-1     T = -25 °C: 9.769067581 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.43354216 V-1     T = -25 °C: 15.56108726 V-1
Break-through voltage: T = +20 °C: 411.5738879 V     T = -25 °C: 374.9827035 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:43:23 CET jreher Assigned to capsule by script
05. Feb 2021 10:57:48 CET jreher Updated box and position via API.
03. Feb 2021 18:23:21 CET jreher Updated box and position via API.
18. Dec 2020 14:00:39 CET jreher Updated box and position via API.
11. Aug 2020 17:37:20 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:51 CET jreher Updated APD location via API.
25. Nov 2019 17:16:46 CET jreher Updated box and position via API.
06. Sep 2019 13:10:25 CEST spankonin Updated APD batch assignment via API.
02. Sep 2019 15:18:13 CEST markus.moritz
08. Jul 2019 14:54:41 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:05 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:14 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:51 CEST Tobias Imported from Hamamatsu datasheet.