RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2701030061 - Archived data from Tue, 11. August 2020 17:37:20 CEST


This is all the information about APD 2701030061. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2701030061
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B06
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.8 V
Dark current: 11 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 74
Position in Box: 6
EP1 batch: 55
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.4463372 V     T = -25 °C: 350.6537898 V
Voltage for Gain 150: T = +20 °C: 394.3057744 V     T = -25 °C: 358.1110922 V
Voltage for Gain 200: T = +20 °C: 398.6647157 V     T = -25 °C: 362.3155938 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.424204786 V-1     T = -25 °C: 4.986571297 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.641087826 V-1     T = -25 °C: 9.24074187 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.98047725 V-1     T = -25 °C: 14.37650333 V-1
Break-through voltage: T = +20 °C: 413.3709301 V     T = -25 °C: 376.8035548 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:57:48 CET jreher Updated box and position via API.
03. Feb 2021 18:23:20 CET jreher Updated box and position via API.
11. Aug 2020 17:37:20 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:51 CET jreher Updated APD location via API.
25. Nov 2019 17:16:45 CET jreher Updated box and position via API.
06. Sep 2019 13:10:24 CEST spankonin Updated APD batch assignment via API.
02. Sep 2019 15:14:57 CEST markus.moritz
08. Jul 2019 14:54:41 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:46:05 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:13 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:50 CEST Tobias Imported from Hamamatsu datasheet.