Show Hamamatsu Avalanche Photo Diode 2701030008 - Archived data from Fri, 18. May 2018 12:01:45 CEST
This is all the information about APD 2701030008. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2701030008 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D05 |
Break-through voltage: | 411 V |
Voltage for Gain 100 (T=+25°C): | 382.5 V |
Dark current: | 7.8E-9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 73 |
Position in Box: | 10 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:57:40 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:23:13 CET | jreher | Updated box and position via API. |
08. Dec 2020 17:18:01 CET | jreher | Assigned to capsule by script |
06. Oct 2020 16:53:08 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:27:07 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:41:40 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:16:41 CET | jreher | Updated box and position via API. |
11. Nov 2019 16:23:52 CET | jreher | Updated APD location via API. |
04. Jul 2019 11:11:46 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:43 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:39 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:13:12 CET | Tobias | Corrected dark current unit. |
21. Aug 2018 10:57:32 CEST | markus.moritz | |
24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
18. May 2018 12:01:45 CEST | Tobias | Imported from Hamamatsu datasheet. |