Show Hamamatsu Avalanche Photo Diode 2701030008 - Archived data from Wed, 03. February 2021 18:23:13 CET
This is all the information about APD 2701030008. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2701030008 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2701030008/1913021279 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | blue |
Manufacturer information: | |
Wafer position: | D05 |
Break-through voltage: | 411 V |
Voltage for Gain 100 (T=+25°C): | 382.5 V |
Dark current: | 7.8 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 73 |
Position in Box: | 10 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 24. Jul 2018 |
Sent for analysis after irradiation: | 21. Aug 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Aug 2018 |
Dose used: | 30 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Aug 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 382.8749456 V T = -25 °C: 347.4459049 V |
Voltage for Gain 150: | T = +20 °C: 390.7300995 V T = -25 °C: 354.842898 V |
Voltage for Gain 200: | T = +20 °C: 395.1045236 V T = -25 °C: 358.9834478 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.526640101 V-1 T = -25 °C: 4.976258738 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.709505399 V-1 T = -25 °C: 9.084531413 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.70691935 V-1 T = -25 °C: 15.63619499 V-1 |
Break-through voltage: | T = +20 °C: 410.7394616 V T = -25 °C: 374.1538119 V |
Notes: | foam |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:57:40 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:23:13 CET | jreher | Updated box and position via API. |
08. Dec 2020 17:18:01 CET | jreher | Assigned to capsule by script |
06. Oct 2020 16:53:08 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:27:07 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:41:40 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:16:41 CET | jreher | Updated box and position via API. |
11. Nov 2019 16:23:52 CET | jreher | Updated APD location via API. |
04. Jul 2019 11:11:46 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:43 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:39 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:13:12 CET | Tobias | Corrected dark current unit. |
21. Aug 2018 10:57:32 CEST | markus.moritz | |
24. May 2018 14:39:23 CEST | Tobias | Updated location to "Bochum". |
18. May 2018 12:01:45 CEST | Tobias | Imported from Hamamatsu datasheet. |