RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2701029993 - Archived data from Tue, 16. February 2021 12:28:25 CET


This is all the information about APD 2701029993. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2701029993
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.7 V
Dark current: 9.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 72
Position in Box: 45
EP1 batch: 53
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.4303742 V     T = -25 °C: 346.788635 V
Voltage for Gain 150: T = +20 °C: 390.2294266 V     T = -25 °C: 354.1175722 V
Voltage for Gain 200: T = +20 °C: 394.5623178 V     T = -25 °C: 358.2201782 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.478464801 V-1     T = -25 °C: 5.031590312 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.812696598 V-1     T = -25 °C: 9.45827542 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.48567457 V-1     T = -25 °C: 15.04101579 V-1
Break-through voltage: T = +20 °C: 410.2712956 V     T = -25 °C: 373.5538042 V
   
Notes:


Version history

Time Author Change comment
15. Apr 2021 16:18:05 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:25 CET jreher Updated box and position via API.
05. Feb 2021 10:57:37 CET jreher Updated box and position via API.
03. Feb 2021 18:23:10 CET jreher Updated box and position via API.
11. Aug 2020 17:37:11 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:32 CET jreher Updated APD location via API.
25. Nov 2019 17:16:39 CET jreher Updated box and position via API.
06. Sep 2019 13:10:02 CEST spankonin Updated APD batch assignment via API.
02. Sep 2019 14:12:53 CEST markus.moritz
08. Jul 2019 14:54:08 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:53 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:11 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:40 CEST Tobias Imported from Hamamatsu datasheet.