RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2610029936 - Archived data from Fri, 05. February 2021 10:57:35 CET


This is all the information about APD 2610029936. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2610029936
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B11
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.9 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 72
Position in Box: 32
EP1 batch: 53
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.7814635 V     T = -25 °C: 344.558546 V
Voltage for Gain 150: T = +20 °C: 387.5827902 V     T = -25 °C: 351.9096473 V
Voltage for Gain 200: T = +20 °C: 391.8966265 V     T = -25 °C: 356.0290993 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.749748628 V-1     T = -25 °C: 4.728107353 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.560949281 V-1     T = -25 °C: 9.641686918 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.96023005 V-1     T = -25 °C: 15.3392322 V-1
Break-through voltage: T = +20 °C: 406.2796127 V     T = -25 °C: 370.3068134 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 18:56:33 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:27:11 CET jreher Updated box and position via API.
05. Feb 2021 10:57:35 CET jreher Updated box and position via API.
03. Feb 2021 18:23:08 CET jreher Updated box and position via API.
11. Aug 2020 17:37:09 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:31 CET jreher Updated APD location via API.
25. Nov 2019 17:16:38 CET jreher Updated box and position via API.
06. Sep 2019 13:09:38 CEST spankonin Updated APD batch assignment via API.
02. Sep 2019 14:02:13 CEST markus.moritz
08. Jul 2019 14:54:07 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:52 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:11 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:36 CEST Tobias Imported from Hamamatsu datasheet.