Show Hamamatsu Avalanche Photo Diode 2608029786 - Archived data from Wed, 16. June 2021 15:53:21 CEST


This is all the information about APD 2608029786. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2608029786
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 403 V
Voltage for Gain 100 (T=+25°C): 374.8 V
Dark current: 13.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 286
Position in Box: 7
EP1 batch: 103
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 374.6703917 V     T = -25 °C: 340.0767506 V
Voltage for Gain 150: T = +20 °C: 382.4564409 V     T = -25 °C: 347.3761187 V
Voltage for Gain 200: T = +20 °C: 386.7971126 V     T = -25 °C: 351.4739191 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.761375074 V-1     T = -25 °C: 4.929324792 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.400375839 V-1     T = -25 °C: 9.164973234 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.62749967 V-1     T = -25 °C: 16.21202675 V-1
Break-through voltage: T = +20 °C: 402.730573 V     T = -25 °C: 366.9081572 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 10:46:37 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:26 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:39 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:21 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:25:11 CET jreher Updated box and position via API.
06. Oct 2020 18:48:26 CEST jreher Updated APD location via API.
11. Aug 2020 18:04:09 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:56 CEST jreher Updated box and position via API.
10. Feb 2020 18:57:11 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 12:23:45 CET jreher Updated APD location via API.
25. Nov 2019 17:31:08 CET jreher Updated box and position via API.
25. Nov 2019 17:16:27 CET jreher Updated box and position via API.
22. Oct 2019 14:41:06 CEST spankonin Updated APD location via API.
22. Oct 2019 14:21:18 CEST jreher Updated APD batch assignment via API.
05. Jul 2019 13:45:35 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:07 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:09 CEST Tobias Imported from Hamamatsu datasheet.