RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2608029779 - Archived data from Wed, 03. February 2021 18:22:54 CET


This is all the information about APD 2608029779. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2608029779
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2608029779/2413026976
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 6.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 70
Position in Box: 19
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.0662692 V     T = -25 °C: 344.6639591 V
Voltage for Gain 150: T = +20 °C: 387.8875365 V     T = -25 °C: 352.0545698 V
Voltage for Gain 200: T = +20 °C: 392.2756184 V     T = -25 °C: 356.2368437 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.554883149 V-1     T = -25 °C: 5.150828504 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.58809105 V-1     T = -25 °C: 9.092917266 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.63098832 V-1     T = -25 °C: 16.88600495 V-1
Break-through voltage: T = +20 °C: 405.6096579 V     T = -25 °C: 371.503161 V
   
Notes: foam


Version history

Time Author Change comment
05. Feb 2021 10:57:21 CET jreher Updated box and position via API.
03. Feb 2021 18:22:54 CET jreher Updated box and position via API.
11. Aug 2020 17:26:46 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:46:08 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:54 CET jreher Updated box and position via API.
27. Nov 2019 19:36:39 CET jreher Updated APD location via API.
25. Nov 2019 17:16:26 CET jreher Updated box and position via API.
25. Nov 2019 17:14:22 CET jreher Updated box and position via API.
04. Jul 2019 11:11:29 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:36 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:13:07 CET Tobias Corrected dark current unit.
21. Aug 2018 11:58:17 CEST markus.moritz
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:05 CEST Tobias Imported from Hamamatsu datasheet.