Subdetector specification:  
Serial: 2608029772
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G06
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 378.5 V
Dark current: 10 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 357
Position in Box: 50
EP1 batch: 50
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.0565958 V     T = -25 °C: 342.9033816 V
Voltage for Gain 150: T = +20 °C: 385.8409968 V     T = -25 °C: 350.2464275 V
Voltage for Gain 200: T = +20 °C: 390.1659176 V     T = -25 °C: 354.3737111 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.655799787 V-1     T = -25 °C: 5.008577036 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.275815495 V-1     T = -25 °C: 9.405499032 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.59897413 V-1     T = -25 °C: 14.93393841 V-1
Break-through voltage: T = +20 °C: 405.1223975 V     T = -25 °C: 369.1547898 V
   
Notes:


Version history

Time Author Change comment
16. May 2022 13:33:13 CEST oafedulidis Updated box and position via API.
28. Apr 2021 13:29:36 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:45:25 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:57:21 CET jreher Updated box and position via API.
03. Feb 2021 18:22:54 CET jreher Updated box and position via API.
11. Aug 2020 17:36:53 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:09 CET jreher Updated APD location via API.
25. Nov 2019 17:16:26 CET jreher Updated box and position via API.
06. Sep 2019 13:08:17 CEST spankonin Updated APD batch assignment via API.
02. Sep 2019 10:30:35 CEST markus.moritz
08. Jul 2019 14:53:21 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:34 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:07 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:02 CEST Tobias Imported from Hamamatsu datasheet.