Subdetector specification:  
Serial: 2608029767
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.2 V
Dark current: 7.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 70
Position in Box: 7
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.6471598 V     T = -25 °C: 343.4843193 V
Voltage for Gain 150: T = +20 °C: 386.4036792 V     T = -25 °C: 350.7926234 V
Voltage for Gain 200: T = +20 °C: 390.7316845 V     T = -25 °C: 354.8923989 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.434105585 V-1     T = -25 °C: 4.593779516 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.168199607 V-1     T = -25 °C: 9.73670077 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.95749327 V-1     T = -25 °C: 15.67247843 V-1
Break-through voltage: T = +20 °C: 405.9208243 V     T = -25 °C: 369.9036034 V
   
Notes: foam, has multiple scratches on its surface (21_08_2018)


Version history

Time Author Change comment
17. Jun 2021 18:45:27 CEST oafedulidis Assigned to capsule by script
05. Feb 2021 10:57:20 CET jreher Updated box and position via API.
03. Feb 2021 18:22:53 CET jreher Updated box and position via API.
18. Dec 2020 14:01:19 CET jreher Updated box and position via API.
11. Aug 2020 17:26:44 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:39 CET jreher Updated APD location via API.
25. Nov 2019 17:16:25 CET jreher Updated box and position via API.
25. Nov 2019 17:14:21 CET jreher Updated box and position via API.
04. Jul 2019 11:11:28 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:35 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:13:06 CET Tobias Corrected dark current unit.
21. Aug 2018 11:32:28 CEST markus.moritz
21. Aug 2018 11:32:09 CEST markus.moritz 9
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:01:00 CEST Tobias Imported from Hamamatsu datasheet.