RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2608029763 - Archived data from Tue, 11. August 2020 17:26:44 CEST


This is all the information about APD 2608029763. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2608029763
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 378.5 V
Dark current: 11.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 357
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.0866128 V     T = -25 °C: 342.860568 V
Voltage for Gain 150: T = +20 °C: 385.8450105 V     T = -25 °C: 350.1832502 V
Voltage for Gain 200: T = +20 °C: 390.1505517 V     T = -25 °C: 354.3004735 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.656187849 V-1     T = -25 °C: 4.931962043 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.628465251 V-1     T = -25 °C: 9.271529479 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.19286399 V-1     T = -25 °C: 16.82385443 V-1
Break-through voltage: T = +20 °C: 405.3607111 V     T = -25 °C: 369.2313337 V
   
Notes: foam


Version history

Time Author Change comment
21. Apr 2021 14:45:25 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:57:20 CET jreher Updated box and position via API.
03. Feb 2021 18:22:53 CET jreher Updated box and position via API.
11. Aug 2020 17:26:44 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:38 CET jreher Updated APD location via API.
25. Nov 2019 17:16:25 CET jreher Updated box and position via API.
25. Nov 2019 17:14:21 CET jreher Updated box and position via API.
04. Jul 2019 11:11:28 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:38 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:35 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:13:06 CET Tobias Corrected dark current unit.
21. Aug 2018 11:53:19 CEST markus.moritz
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:57 CEST Tobias Imported from Hamamatsu datasheet.