Serial: 2608029748
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D13
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 375 V
Dark current: 11.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 215
Position in Box: 45
EP1 batch: 50
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.1285423 V     T = -25 °C: 340.7617665 V
Voltage for Gain 150: T = +20 °C: 382.9287341 V     T = -25 °C: 348.0049121 V
Voltage for Gain 200: T = +20 °C: 387.2992625 V     T = -25 °C: 352.0700778 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.605260317 V-1     T = -25 °C: 5.124006102 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.071463049 V-1     T = -25 °C: 9.656368328 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.04188171 V-1     T = -25 °C: 15.47262363 V-1
Break-through voltage: T = +20 °C: 403.0827876 V     T = -25 °C: 367.1650926 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:55:06 CET oafedulidis Assigned to capsule by script
01. Dec 2021 12:56:25 CET oafedulidis Updated box and position via API.
03. May 2021 10:24:30 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:57:17 CET jreher Updated box and position via API.
03. Feb 2021 18:22:49 CET jreher Updated box and position via API.
11. Aug 2020 17:39:45 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:01 CET jreher Updated APD location via API.
25. Nov 2019 17:16:23 CET jreher Updated box and position via API.
13. Sep 2019 10:31:36 CEST jgrochowski Updated APD batch assignment via API.
03. Sep 2019 15:14:57 CEST markus.moritz
08. Jul 2019 14:53:20 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:29 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:06 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:52 CEST Tobias Imported from Hamamatsu datasheet.