RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2608029747 - Archived data from Wed, 03. February 2021 18:22:49 CET


This is all the information about APD 2608029747. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2608029747
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2303024334/2608029747
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F03
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 381.1 V
Dark current: 8.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 69
Position in Box: 38
EP1 batch: 50
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.3162117 V     T = -25 °C: 346.0394188 V
Voltage for Gain 150: T = +20 °C: 389.1605991 V     T = -25 °C: 353.446871 V
Voltage for Gain 200: T = +20 °C: 393.5410808 V     T = -25 °C: 357.6005364 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.505131664 V-1     T = -25 °C: 4.887488237 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.84689568 V-1     T = -25 °C: 9.060778001 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.45189196 V-1     T = -25 °C: 16.07209046 V-1
Break-through voltage: T = +20 °C: 408.0441813 V     T = -25 °C: 373.1809765 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:57:17 CET jreher Updated box and position via API.
03. Feb 2021 18:22:49 CET jreher Updated box and position via API.
11. Aug 2020 17:39:47 CEST jreher Updated APD characteristics via API.
25. Jun 2020 11:25:59 CEST jreher Assigned to capsule by script
20. Feb 2020 13:34:33 CET jreher Updated box and position via API.
27. Nov 2019 19:41:01 CET jreher Updated APD location via API.
25. Nov 2019 17:16:23 CET jreher Updated box and position via API.
17. Sep 2019 11:30:59 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:40:51 CEST markus.moritz
08. Jul 2019 14:53:20 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:29 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:06 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:51 CEST Tobias Imported from Hamamatsu datasheet.