RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2520029119 - Archived data from Wed, 03. February 2021 18:22:47 CET


This is all the information about APD 2520029119. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2520029119
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2518028948/2520029119
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.8 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: No
Storage Box: 69
Position in Box: 26
EP1 batch: 50
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 26. Aug 2019
Sent for analysis after irradiation: 02. Sep 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Aug 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 31. Aug 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.5134269 V     T = -25 °C: 344.3356657 V
Voltage for Gain 150: T = +20 °C: 387.3588142 V     T = -25 °C: 351.7171638 V
Voltage for Gain 200: T = +20 °C: 391.7221164 V     T = -25 °C: 355.8459368 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.470554111 V-1     T = -25 °C: 4.811209344 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.677700437 V-1     T = -25 °C: 9.797201482 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.12737543 V-1     T = -25 °C: 15.63425604 V-1
Break-through voltage: T = +20 °C: 407.0007739 V     T = -25 °C: 371.0387049 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:57:15 CET jreher Updated box and position via API.
03. Feb 2021 18:22:47 CET jreher Updated box and position via API.
11. Aug 2020 17:39:45 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:52:41 CEST jreher Assigned to capsule by script
13. Feb 2020 14:21:51 CET jreher Updated box and position via API.
27. Nov 2019 19:41:00 CET jreher Updated APD location via API.
25. Nov 2019 17:16:22 CET jreher Updated box and position via API.
17. Sep 2019 11:30:58 CEST jgrochowski Updated APD batch assignment via API.
04. Sep 2019 13:41:13 CEST markus.moritz
08. Jul 2019 14:53:19 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:28 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:05 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:46 CEST Tobias Imported from Hamamatsu datasheet.