RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2520029106 - Archived data from Thu, 15. April 2021 17:01:18 CEST


This is all the information about APD 2520029106. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2520029106
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.7 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 69
Position in Box: 13
EP1 batch: 49
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.6266372 V     T = -25 °C: 343.6309514 V
Voltage for Gain 150: T = +20 °C: 386.4833231 V     T = -25 °C: 350.9355283 V
Voltage for Gain 200: T = +20 °C: 390.8538337 V     T = -25 °C: 355.0411227 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.383833555 V-1     T = -25 °C: 4.713745462 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.517475791 V-1     T = -25 °C: 9.59901589 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.62568739 V-1     T = -25 °C: 15.22228639 V-1
Break-through voltage: T = +20 °C: 406.1780998 V     T = -25 °C: 369.9065574 V
   
Notes:


Version history

Time Author Change comment
25. Oct 2021 14:01:51 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:18 CEST jreher Updated box and position via API.
05. Feb 2021 10:57:14 CET jreher Updated box and position via API.
03. Feb 2021 18:22:46 CET jreher Updated box and position via API.
11. Aug 2020 17:39:43 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:41:00 CET jreher Updated APD location via API.
25. Nov 2019 17:16:21 CET jreher Updated box and position via API.
13. Sep 2019 10:31:36 CEST jgrochowski Updated APD batch assignment via API.
29. Jul 2019 14:36:38 CEST markus.moritz
08. Jul 2019 14:53:05 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:28 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:05 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:41 CEST Tobias Imported from Hamamatsu datasheet.