Subdetector specification:  
Serial: 2520029105
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F10
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.1 V
Dark current: 4.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 215
Position in Box: 36
EP1 batch: 49
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.7574603 V     T = -25 °C: 341.8649509 V
Voltage for Gain 150: T = +20 °C: 384.5848578 V     T = -25 °C: 349.1652996 V
Voltage for Gain 200: T = +20 °C: 388.9391241 V     T = -25 °C: 353.2799261 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.692714699 V-1     T = -25 °C: 5.028975157 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.340348492 V-1     T = -25 °C: 9.380469931 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.51828721 V-1     T = -25 °C: 14.75604135 V-1
Break-through voltage: T = +20 °C: 404.9586104 V     T = -25 °C: 368.6926046 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:32:02 CET oafedulidis Assigned to capsule by script
17. May 2021 09:15:16 CEST oafedulidis Updated box and position via API.
03. May 2021 10:24:29 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:57:13 CET jreher Updated box and position via API.
03. Feb 2021 18:22:46 CET jreher Updated box and position via API.
11. Aug 2020 17:39:43 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:40:59 CET jreher Updated APD location via API.
25. Nov 2019 17:16:21 CET jreher Updated box and position via API.
13. Sep 2019 10:31:35 CEST jgrochowski Updated APD batch assignment via API.
29. Jul 2019 14:36:11 CEST markus.moritz
08. Jul 2019 14:53:05 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:27 CEST jreher Updated APD location via API.
03. Jan 2019 00:13:05 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:41 CEST Tobias Imported from Hamamatsu datasheet.