RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2520029087 - Archived data from Wed, 03. February 2021 18:22:42 CET


This is all the information about APD 2520029087. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2520029087
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2417027267/2520029087
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.6 V
Dark current: 4.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 68
Position in Box: 44
EP1 batch: 48
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.6281579 V     T = -25 °C: 345.3416243 V
Voltage for Gain 150: T = +20 °C: 388.5152592 V     T = -25 °C: 352.717527 V
Voltage for Gain 200: T = +20 °C: 392.8926587 V     T = -25 °C: 356.8733928 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.377463852 V-1     T = -25 °C: 4.80731368 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.28211564 V-1     T = -25 °C: 9.691965507 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.48659896 V-1     T = -25 °C: 15.31276731 V-1
Break-through voltage: T = +20 °C: 408.8996735 V     T = -25 °C: 372.5498522 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:57:09 CET jreher Updated box and position via API.
03. Feb 2021 18:22:42 CET jreher Updated box and position via API.
11. Aug 2020 17:33:45 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:46:53 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:49 CET jreher Updated box and position via API.
27. Nov 2019 19:40:51 CET jreher Updated APD location via API.
25. Nov 2019 17:16:18 CET jreher Updated box and position via API.
05. Aug 2019 16:55:01 CEST jreher Updated APD batch assignment via API.
29. Jul 2019 14:21:50 CEST markus.moritz
08. Jul 2019 14:52:15 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:22 CEST jreher Updated APD location via API.
01. Jul 2019 12:41:24 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:13:04 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:35 CEST Tobias Imported from Hamamatsu datasheet.