RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2520029062 - Archived data from Wed, 21. April 2021 11:03:11 CEST


This is all the information about APD 2520029062. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2520029062
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.9 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 68
Position in Box: 19
EP1 batch: 48
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.8368125 V     T = -25 °C: 342.7553423 V
Voltage for Gain 150: T = +20 °C: 385.6079588 V     T = -25 °C: 350.0635054 V
Voltage for Gain 200: T = +20 °C: 389.9287346 V     T = -25 °C: 354.1844777 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.692380313 V-1     T = -25 °C: 5.036636509 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.318671197 V-1     T = -25 °C: 9.41487912 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.55152322 V-1     T = -25 °C: 14.73957162 V-1
Break-through voltage: T = +20 °C: 405.4015392 V     T = -25 °C: 369.3271468 V
   
Notes:


Version history

Time Author Change comment
25. Sep 2021 15:59:44 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:03:11 CEST jreher Updated box and position via API.
05. Feb 2021 10:57:06 CET jreher Updated box and position via API.
03. Feb 2021 18:22:39 CET jreher Updated box and position via API.
11. Aug 2020 17:33:41 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:40:49 CET jreher Updated APD location via API.
25. Nov 2019 17:16:16 CET jreher Updated box and position via API.
05. Aug 2019 16:54:51 CEST jreher Updated APD batch assignment via API.
29. Jul 2019 13:57:52 CEST markus.moritz
08. Jul 2019 14:52:13 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:45:20 CEST jreher Updated APD location via API.
01. Jul 2019 12:41:22 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:13:03 CET Tobias Corrected dark current unit.
24. May 2018 14:39:23 CEST Tobias Updated location to "Bochum".
18. May 2018 12:00:26 CEST Tobias Imported from Hamamatsu datasheet.