Subdetector specification: | |
---|---|
Serial: | 2408026513 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 12 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D09 |
Break-through voltage: | 411 V |
Voltage for Gain 100 (T=+25°C): | 382.2 V |
Dark current: | 5.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 12 |
Position in Box: | 18 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 12. Nov 2018 |
Sent for analysis after irradiation: | 13. Dec 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 07. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:49:17 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:15:26 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:12:53 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:53:25 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:21:42 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:31:31 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:11:50 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:07:50 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:46:17 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:31:12 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 15:03:01 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:12:58 CET | Tobias | Corrected dark current unit. |
13. Dec 2018 14:05:24 CET | markus.moritz | |
30. Nov 2018 08:57:51 CET | markus.moritz | |
12. Jan 2018 13:16:54 CET | Tobias | Imported from Hamamatsu datasheet. |