RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2406026383 - Archived data from Mon, 17. May 2021 09:17:49 CEST


This is all the information about APD 2406026383. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2406026383
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E01
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 391.7 V
Dark current: 3.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 2
Position in Box: 22
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.3222488 V     T = -25 °C: 355.9312621 V
Voltage for Gain 150: T = +20 °C: 400.3013402 V     T = -25 °C: 363.5784917 V
Voltage for Gain 200: T = +20 °C: 404.7287403 V     T = -25 °C: 367.8443102 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.446774264 V-1     T = -25 °C: 4.788109971 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.61017871 V-1     T = -25 °C: 8.698602064 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.99522683 V-1     T = -25 °C: 15.19429545 V-1
Break-through voltage: T = +20 °C: 419.4415037 V     T = -25 °C: 383.0130656 V
   
Notes: foam


Version history

Time Author Change comment
27. Sep 2021 16:13:07 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:17:49 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:47:49 CET jreher Updated box and position via API.
03. Feb 2021 18:14:08 CET jreher Updated box and position via API.
11. Aug 2020 17:20:05 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:29:41 CET jreher Updated APD location via API.
25. Nov 2019 17:11:01 CET jreher Updated box and position via API.
03. Jul 2019 20:03:57 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:32 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:27 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:08 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:55:55 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:55 CET Tobias Corrected dark current unit.
21. Aug 2018 09:36:04 CEST markus.moritz
12. Jan 2018 13:16:52 CET Tobias Imported from Hamamatsu datasheet.