Subdetector specification:  
Serial: 2406026371
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.1 V
Dark current: 5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 2
Position in Box: 11
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.8656613 V     T = -25 °C: 351.8146817 V
Voltage for Gain 150: T = +20 °C: 395.7589497 V     T = -25 °C: 359.3481116 V
Voltage for Gain 200: T = +20 °C: 400.1453111 V     T = -25 °C: 363.5776364 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.635861479 V-1     T = -25 °C: 4.916897554 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.164482684 V-1     T = -25 °C: 8.994593579 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.33495721 V-1     T = -25 °C: 15.90559394 V-1
Break-through voltage: T = +20 °C: 415.7741814 V     T = -25 °C: 379.2897617 V
   
Notes: foam


Version history

Time Author Change comment
10. Jun 2022 12:17:10 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:01:37 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:47:48 CET jreher Updated box and position via API.
03. Feb 2021 18:14:07 CET jreher Updated box and position via API.
11. Aug 2020 17:20:03 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:29:40 CET jreher Updated APD location via API.
25. Nov 2019 17:10:59 CET jreher Updated box and position via API.
03. Jul 2019 20:03:56 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:27 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:07 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:55:54 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:54 CET Tobias Corrected dark current unit.
21. Aug 2018 09:26:01 CEST markus.moritz
12. Jan 2018 13:16:52 CET Tobias Imported from Hamamatsu datasheet.