RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2406026369 - Archived data from Mon, 30. August 2021 14:07:38 CEST


This is all the information about APD 2406026369. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2406026369
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D01
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 393.2 V
Dark current: 3.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 2
Position in Box: 10
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.4289242 V     T = -25 °C: 356.2870819 V
Voltage for Gain 150: T = +20 °C: 400.3990543 V     T = -25 °C: 363.9515302 V
Voltage for Gain 200: T = +20 °C: 404.7700771 V     T = -25 °C: 368.1814921 V
Gain/Voltage slope at M = 100: T = +20 °C: 5.008140964 V-1     T = -25 °C: 5.330901756 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.158498598 V-1     T = -25 °C: 8.992814172 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.774993 V-1     T = -25 °C: 14.06051355 V-1
Break-through voltage: T = +20 °C: 419.9838183 V     T = -25 °C: 383.8425361 V
   
Notes: foam


Version history

Time Author Change comment
15. Nov 2022 12:55:47 CET oafedulidis Assigned to capsule by script
30. Aug 2021 14:07:38 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:47:48 CET jreher Updated box and position via API.
03. Feb 2021 18:14:07 CET jreher Updated box and position via API.
11. Aug 2020 17:20:03 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:29:40 CET jreher Updated APD location via API.
25. Nov 2019 17:10:59 CET jreher Updated box and position via API.
03. Jul 2019 20:03:56 CEST jreher Updated APD location via API.
13. Jun 2019 11:23:43 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:45:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:26 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:06 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:55:16 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:54 CET Tobias Corrected dark current unit.
21. Aug 2018 09:23:16 CEST markus.moritz
12. Jan 2018 13:16:52 CET Tobias Imported from Hamamatsu datasheet.