RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2405026294 - Archived data from Wed, 03. February 2021 18:15:05 CET


This is all the information about APD 2405026294. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2405026294
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2405026294/2410026699
Unit: #1558 (barcode 1309016617)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: B09
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.4 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 9
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.0277219 V     T = -25 °C: 348.378946 V
Voltage for Gain 150: T = +20 °C: 391.8244685 V     T = -25 °C: 355.8235854 V
Voltage for Gain 200: T = +20 °C: 396.1508003 V     T = -25 °C: 359.9884185 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.653885456 V-1     T = -25 °C: 4.761819228 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.246259037 V-1     T = -25 °C: 9.678458652 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.52291332 V-1     T = -25 °C: 15.32977353 V-1
Break-through voltage: T = +20 °C: 411.1642072 V     T = -25 °C: 374.8793291 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:58 CET jreher Updated box and position via API.
03. Feb 2021 18:15:05 CET jreher Updated box and position via API.
08. Dec 2020 17:09:27 CET jreher Assigned to capsule by script
06. Oct 2020 16:51:40 CEST jreher Updated box and position via API.
11. Aug 2020 17:21:16 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:59 CET jreher Updated APD location via API.
25. Nov 2019 17:11:37 CET jreher Updated box and position via API.
04. Jul 2019 11:06:03 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:06 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:01 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:02:27 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:51 CET Tobias Corrected dark current unit.
13. Dec 2018 14:04:13 CET markus.moritz
23. Nov 2018 11:58:33 CET markus.moritz
12. Jan 2018 13:16:51 CET Tobias Imported from Hamamatsu datasheet.